Ⅱ. Technical Specification
1.Range and Accuracy
|
Measurement function
|
Measuring range
|
Accuracy
|
Resolution
|
|
Two-three-four-wire method to measure grounding resistance (Re)
|
0.00Ω~29.99Ω
|
±2%rdg±5dgt(Note 1)
|
0.01Ω
|
|
30.0Ω~299.9Ω
|
±2%rdg±3dgt
|
0.1Ω
|
|
300Ω~2999Ω
|
±2%rdg±3dgt
|
1Ω
|
|
3.00kΩ~30.00kΩ
|
±2%rdg±3dgt
|
10Ω
|
|
DC resistance (R—)
|
0.0Ω~299.9Ω
|
±2%rdg±3dgt
|
0.1Ω
|
|
300Ω~2999Ω
|
±2%rdg±3dgt
|
1Ω
|
|
3.00kΩ~30.00kΩ
|
±2%rdg±3dgt
|
10Ω
|
|
Earth Resistance (Re) by Selection Method
|
0.00Ω~29.99Ω
|
±2%rdg±5dgt(Note 1)
|
0.01Ω
|
|
30.0Ω~299.9Ω
|
±2%rdg±3dgt
|
0.1Ω
|
|
300Ω~3000Ω
|
±2%rdg±3dgt
|
1Ω
|
|
Double clamp method to measure earth resistance (Re)
|
0.01Ω~0.99Ω
|
±10%rdg±10dgt
|
0.01Ω
|
|
1.0Ω~9.9Ω
|
0.1Ω
|
|
10Ω~100Ω
|
1Ω
|
|
Soil resistivity (ρ)
|
0.00Ωm~99.99Ωm
|
ρ=2πaR (Note 2)
|
0.01Ωm
|
|
100.0Ωm~999.9Ωm
|
0.1Ωm
|
|
1000Ωm~9999Ωm
|
1Ωm
|
|
10.00kΩm~99.99kΩm
|
10Ωm
|
|
100.0kΩm~999.9kΩm
|
100Ωm
|
|
1000kΩm~9999kΩm
|
1kΩm
|
|
ground voltage
|
AC 0.00~100.0V
|
±2%rdg±3dgt
|
0.01V
|
|
Alternating current
|
AC 0.0mA~1000A
|
±2%rdg±3dgt
|
0.1mA
|
Note: 1. Reference condition: Accuracy when Rh Rs<100Ω.
Working conditions: Rh max=3kΩ+100R<50kΩ; Rs max=3kΩ+100R<50kΩ
- It depends on the measurement accuracy of R, π=3.14, a: 1 m~100m;
- General Specifications
|
Features
|
Ground resistance, soil resistivity, DC resistance, ground voltage, AC current,
|
|
Ambient temperature and humidity
|
23℃±5℃, below 75%rh
|
|
Interference voltage
|
<20V (should be avoided)
|
|
Disturbance current
|
<2A (should be avoided)
|
|
Electrode spacing when measuring R
|
a>5d
|
|
Electrode spacing when measuring ρ
|
a>20h
|
|
Power supply
|
DC 6V 4.5Ah lead-acid battery, continuous standby for more than 100 hours
|
|
Backlight
|
Controllable backlight, suitable for dark places
|
|
Measurement method
|
Precision four-wire, three-wire method measurement, simple two-wire method, selection method, double clamp method to measure grounding resistance
|
|
Measurement methods
|
Two-three-four-wire method measurement: pole-changing method, measuring current 20mA Max
Soil Resistivity: Quadrupole Method
Selection method measurement: pole-changing method, measuring current 20mA Max
Double clamp method: non-contact mutual inductance measurement method, test current 1mA Max
DC resistance: pole changing method
AC current: average value rectification (clamp)
Ground voltage: Average value rectification (between S-ES interface)
|
|
Test voltage waveform
|
sine wave
|
|
Test frequency
|
128Hz
|
|
Short circuit test current
|
AC 20mA max
|
|
Open circuit test voltage
|
AC 28V max
|
|
Electrode Spacing Range
|
1m~100m
|
|
Display mode
|
4-digit large LCD display with backlight
|
|
Measurement instructions
|
LED flashing indication during measurement
|
|
LCD size
|
111mm×68mm
|
|
LCD display field
|
108mm×65mm
|
|
Meter size
|
Length, width and height: 277.2mm×227.5mm×153mm
|
|
Current clamp size
|
Length, thickness and height: 101mm×27mm×214mm
|
|
Test line
|
4 strips: 15m for red, 15m for black, 10m for yellow, 10m for green
|
|
Simple test lead
|
2: Yellow 1.5m, 1 green 1.5m each
|
|
Auxiliary ground rod
|
4 pieces: φ10mm×200mm
|
|
Current clamp
|
2: Banana plugs
|
|
Current clamp diameter
|
φ50mm
|
|
Current clamp leads
|
2m long
|
|
Measure time
|
AC current: about 2 times/second
Voltage to ground: about 2 times/second
Grounding resistance, soil resistivity: about 7 seconds/time
|
|
Line voltage
|
AC 100V or less measurement (the ground voltage measurement function cannot be used to measure commercial power)
|
|
USB interface
|
With a USB interface, the stored data can be uploaded to the computer through the software
|
|
Communication line
|
1 USB communication cable, 1.5m long
|
|
Data retention
|
"HOLD" symbol indication when holding data
|
|
Data storage
|
500 groups, "MEM" storage indication, displaying "FULL" symbol means the storage is full
|
|
Data access
|
"MR" symbol indication when viewing data
|
|
Overflow display
|
"OL" symbol indication when overrange overflow
|
|
Current clamp low current indication
|
When the selection method or the double-clamp method is used for measurement, when the current signal received by CT2 is lower than 0.5mA, the symbol “ ” will be displayed, and the clamping direction of the CT2 current clamp should be checked at this time.
|
|
Interference test
|
Automatically identify interference signals, and the "NOISE" symbol indicates when the interference voltage is higher than 5V
|
|
Auxiliary ground test
|
With auxiliary grounding resistance value test function, 0.00kΩ~30.00kΩ (Rh max=3kΩ+100R<50kΩ; Rs max=3kΩ+100R<50kΩ)
|
|
Alarm function
|
When the measured value exceeds the alarm setting value, an alarm prompt will be issued
|
|
Battery voltage
|
Real-time display of battery power, reminding to charge in time when the battery voltage is low
|
|
Automatic shut-down
|
The meter shuts down after about 15 minutes of inactivity
|
|
Power consumption
|
Standby: 40mA Max (backlight off)
|
|
Turn on the backlight: 43mA Max
|
|
Measurement: 120mA Max (backlight off)
|
|
Quality
|
Meter: 2430g (including battery)
|
|
Current clamp: 940g (2 pieces)
|
|
Test line: 1300g (including simple test line)
|
|
Auxiliary ground rod: 850g (4 pieces)
|
|
Working temperature and humidity
|
-10℃~40℃; below 80%rh
|
|
Storage temperature and humidity
|
-20℃~60℃; below 70%rh
|
|
Overload protection
|
Measuring ground resistance: AC 280V/3 seconds between each port of H-E and S-ES
|
|
Insulation resistance
|
Above 20MΩ (500V between circuit and case)
|
|
Pressure resistance
|
AC 3700V/rms (between circuit and case)
|
|
Electromagnetic properties
|
IEC61326(EMC)
|
|
Suitable for safety regulations
|
IEC61010-1 (CAT III 300V, CAT IV 150V, pollution degree 2); IEC61010-031;
IEC61557-1 (grounding resistance);
IEC61557-5 (soil resistivity);
JJG 366-2004 (earth resistance meter);
JJG 1054-2009 (Clamp Earth Resistance Tester)
|
Ⅲ. Packing List
|
Meter
|
1 set
|
|
Instrument box
|
1
|
|
Auxiliary ground rod
|
4 sticks
|
|
Current clamp
|
2
|
|
Monitoring software CD
|
1 serving
|
|
USB communication cable
|
1
|
|
Test line
|
4
|
|
Simple test lead
|
2 pieces
|
|
6V battery (built-in)
|
1
|
|
Charger
|
1
|
|
User Manual Warranty
|
1 serving
|
Condition
PS:What you see is what you get. After receiving the goods, please take an unpacking video for record. If there is any issue with the product, you can return or exchange it within 15 days.
*** Payment ***
Orders must be paid for within 5 Business days.
Once payment is received & verified, we will send out the shipment within 5 business days, excepting holidays.
*** Order Processing & Handling Time ***
Your order will be shipped within 5 business days (excluding Friday, Saturday, and Jewish Holidays) following confirmation of payment.
This handling time is needed for special international secure packaging and paperwork.
You will be informed by Email of any unexpected shipping delays, should the situation warrant.
*** Delivery Time ***
Your order will be shipped from China Guangzhou (Registered mail with tracking).
Full tracking information will be provided to you.
Once your order is shipped, it normally takes : ( Please read the purchase description)
Regular Air Mail (Economy - Post Office ) : 11-30 business days
EMS (Standard) : 8-15 days for door-to-door delivery.
UPS /DHL (Buyer Request ): 6-10 days
N.B. ("note well") These shipping times are estimations only. Receipt of shipment may take longer, depending on the local situation in your country. Delivery time varies according to destination.
Free shipping within the United States. For remote areas and countries in South America, please consult our customer service to find out whether the item can be shipped. There may also be a possibility of additional shipping fees.